Make sure all accessories
are linked to the bonding
connector and connected
to pack.
Make sure the spa pack door
is closed.
Turn on the breaker.
Press Select button to change
breaker setting.
The in.scan display will show
the breaker setting menu.
It is important to specify the
current rating of the GFCI used
to insure safe and ef cient
current management (and no
GFCI trippings).
Bonding lug
Br values displayed by the
system correspond to 0.8 of
the maximum amperage
capacity of the GFCI.
GFCI Br
60 Amp 48 Amp
50 Amp 40 Amp
40 Amp 32 Amp
30 Amp 24 Amp
Note: Every OEM has its own preset
con gurations.
Use Change button to set the
current breaker rating then
press Select button.
All receptacles will match
the corresponding female
connection on the spa pack.
No connectors should remain
unplugged. Use blank plugs to
ll unused connectors.