Input voltage issue
Check input terminal connections to make sure they are
correctly wired & tighten (see connection section)
Have a certi ed electrician verify the quality of the power lines.
You should have 240v between L1 & L2 and 120v between each
line and neutral.
SP - F1
In.xm Fuse F1 is blown
Replace the blown fuse F1 with an identically rated replacement
(SC-20, SC-25, etc.)
If new fuse blows, disconnect fan, blower, circulation pump &
ber optic.
Replace fuse and reconnect all components, one at a time,
until fuse blows.
Replace component that caused fuse to blow.
SP corrective actions