34
in.xmaccessories corrective actions
P1 - ER
Pump 1 not responding
• Make sure Pump 1 is connected properly (when connecting plug,
you should hear it click).
• Manually change output status (on/off) of Pump 1 and cycle
through all possible states (i.e. low, high, off).
• Reset spa pack by pressing Select key twice.
• If error does not clear, problem is most likely with Pump 1.
It will need to be replaced.
• If Pump 1 is replaced, a new learning routine must be performed
(see procedure page 15).
P2 - ER
Pump 2 not responding
• Make sure Pump 2 is connected properly.
• Manually change output status (on/off) of Pump 2 and cycle
through all possible states (i.e. low and high speeds).
Reset spa pack.
• If error does not clear, problem is probably with Pump 2.
It will need to be replaced.
• If Pump 2 is replaced, a new learning routine must be performed
(see procedure page 15).
• If a pump error is detected during a fl ow check, the pump will remain activated while performing this task, for this reason, a 9 min. delay
might be required to clear error.
• If the spa is equipped with an in.k600 menu driven, the learned current value can be verifi ed (see viewing current management data
section for more details). Furthermore, if the current value learned by the in.xm spa control is not appropriate, it can trigger false
Pump-ER error codes.